Victorian terraced houses with bay windows and gables

Who we help

Every property type we work on — from a mid-terrace to a block of flats.

Recommendations and prices change with your property type: a mid-terrace is never offered side-wall insulation, a top-floor flat gets its loft, a ground-floor flat its floor, and blocks route to a whole-building survey.

17 property types

Houses

Detached to mid-terrace, bungalows to farmhouses, period homes to new builds — each loses heat differently, so the usual measures and prices change with the type.

Detached house

Typical construction
Any age; cavity or solid walls; large roof and floor
Where heat is lost
Four exposed walls, large roof, ground floor
Usual measures
Loft, cavity or EWI, floor, glazing, solar, heat pump
Watch-outs
Biggest heat loss; best for whole-house packages

Price column: Detached

Semi-detached house

Typical construction
Mostly 1920s–1970s cavity walls; some Victorian solid
Where heat is lost
Three exposed walls and roof
Usual measures
Loft, cavity (or extraction and refill), floor, EWI on side and rear
Watch-outs
Match the neighbour's look on the front

Price column: Semi / end-terrace

End-of-terrace

Typical construction
Victorian solid walls or post-war cavity
Where heat is lost
Gable wall, roof, rear extension
Usual measures
EWI or IWI on gable, loft, floor, room-in-roof
Watch-outs
Gable wall is the main loss

Price column: Semi / end-terrace

Mid-terrace

Typical construction
Mostly Victorian and Edwardian solid brick; post-war cavity
Where heat is lost
Front and rear walls, roof, floor
Usual measures
Loft or room-in-roof, IWI or rear EWI, suspended floor
Watch-outs
Front often in conservation area

Price column: Mid-terrace

Townhouse

Typical construction
Georgian to modern; tall solid or cavity walls
Where heat is lost
Tall walls, roof, stairwell
Usual measures
IWI, roof, glazing, MVHR in modern ones
Watch-outs
Scaffolding and access costs

Price column: Semi / end-terrace

Mews house and cottage

Typical construction
Small, solid walls, low ceilings
Where heat is lost
Walls and roof
Usual measures
Breathable IWI, loft, floor
Watch-outs
Space-saving thin systems

Price column: Mid-terrace

Detached bungalow

Typical construction
1950s–1980s cavity; large loft and floor area
Where heat is lost
Roof and floor are a big share
Usual measures
Loft (large area), cavity, floor, solar on large roof
Watch-outs
Heat pump friendly; single storey EWI is quick

Price column: Bungalow

Semi and terraced bungalow

Typical construction
Cavity walls
Where heat is lost
Roof and floor
Usual measures
Loft, cavity, floor
Watch-outs
Good value per £

Price column: Bungalow

Chalet and dormer bungalow

Typical construction
Room-in-roof upstairs
Where heat is lost
Sloping ceilings, dormers, stud walls
Usual measures
Room-in-roof insulation, dormer cheeks, floor
Watch-outs
Often missed by competitors

Price column: Bungalow

Period home

Typical construction
Solid brick or stone, suspended floors, sash windows
Where heat is lost
Walls, floor draughts, windows
Usual measures
Breathable IWI, floor, sash upgrades, secondary glazing, draught-proofing
Watch-outs
Moisture risk: breathable materials only

Price column: Semi / end-terrace

1930s home

Typical construction
Early cavity walls, bay windows, suspended floors
Where heat is lost
Bays, floor, unfilled cavities
Usual measures
Cavity fill, bay insulation, floor, loft
Watch-outs
Check cavity ties and width

Price column: Semi / end-terrace

Post-war and ex-council house

Typical construction
Cavity, some non-traditional
Where heat is lost
Walls and roof
Usual measures
Cavity or EWI, loft, glazing
Watch-outs
Identify construction first

Price column: Semi / end-terrace

Non-traditional / system-built

Typical construction
Concrete panels, no-fines concrete, steel or timber frame
Where heat is lost
Thin uninsulated walls
Usual measures
EWI (often the only route), loft, floor
Watch-outs
Structural survey; some PRC types need repair to be mortgageable

Price column: Semi / end-terrace

Listed building or conservation area

Typical construction
Historic fabric
Where heat is lost
Walls, windows, roof
Usual measures
Breathable IWI, thermal lime render, secondary glazing, loft, floor
Watch-outs
Listed building consent; Article 4; no EWI on fronts without planning

Price column: Semi / end-terrace

Farmhouse, barn conversion or rural home

Typical construction
Stone, timber, off-gas-grid
Where heat is lost
Walls, roof, oil heating
Usual measures
Breathable IWI, roof, floor, heat pump, solar
Watch-outs
Oil and LPG homes: biggest bill savings

Price column: Detached

New build or self-build

Typical construction
Timber frame, masonry, ICF, SIPs
Where heat is lost
Usually low
Usual measures
ICF, SIPs, full-fill cavity, Part L/Future Homes design, SAP calcs
Watch-outs
Design-stage SAP and air testing

Quote after survey

Park and mobile home

Typical construction
Lightweight timber or steel
Where heat is lost
Walls, floor, roof
Usual measures
External insulation kits, underfloor insulation (with a specialist partner)
Watch-outs
Specialist systems only

Quote after survey

9 property types

Flats and blocks of flats

Which insulation suits a flat depends on its floor and its lease. Whole blocks start with a block survey and follow the fire safety rules for their height.
Blocks of flats

Converted flat

Typical construction
Victorian or Edwardian solid walls
Where heat is lost
External walls, top-floor roof, ground floor
Usual measures
IWI, loft (top flat), floor (ground flat), sash upgrades
Watch-outs
Freeholder consent for external work

Price column: Flat / block

Purpose-built flat

Typical construction
Cavity or concrete frame
Where heat is lost
External walls, windows
Usual measures
IWI, glazing, draught-proofing
Watch-outs
Lease and freeholder rules

Price column: Flat / block

Ground-floor, top-floor flat or maisonette

Typical construction
Varies
Where heat is lost
Floor (ground), roof (top)
Usual measures
Floor or loft and roof insulation, EWI via block works
Watch-outs
Maisonettes often have own loft

Price column: Flat / block

Mansion block

Typical construction
Edwardian solid brick, large windows
Where heat is lost
Walls, windows, roof
Usual measures
IWI, secondary glazing, roof, communal works
Watch-outs
Conservation and leaseholder process

Price column: Flat / block

Ex-local-authority flat or maisonette

Typical construction
Concrete, cavity, system-built
Where heat is lost
Walls, roof, windows
Usual measures
Whole-block EWI, roof, windows
Watch-outs
Works usually via council or freeholder

Price column: Flat / block

Low-rise block

Typical construction
Masonry or frame
Where heat is lost
Walls, flat roof
Usual measures
Whole-block EWI, flat roof, cavity, windows, communal heating
Watch-outs
Section 20 consultation for leaseholders

Priced after survey

Mid-rise block

Typical construction
Frame or masonry
Where heat is lost
Walls, roof, balconies
Usual measures
Non-combustible EWI (mineral wool), roof, windows
Watch-outs
Fire risk appraisal of external walls (PAS 9980)

Priced after survey

High-rise block

Typical construction
Concrete frame
Where heat is lost
Walls, roof, balconies
Usual measures
Non-combustible insulation only, roof, windows, communal heating
Watch-outs
Combustible materials banned in external walls; Building Safety Regulator approval for works

Priced after survey

HMO and student housing

Typical construction
Mixed
Where heat is lost
Walls, roof
Usual measures
Loft, IWI, fire-safe EWI, acoustic insulation
Watch-outs
HMO licence and MEES for landlords

Price column: Semi / end-terrace

8 property types

Commercial and public buildings

Offices, warehouses, schools, hotels, care homes and portfolios — measured and priced per m² after a survey, and planned around how the building runs.
Commercial enquiries

Offices, retail and shopfronts

Typical construction
Mixed
Where heat is lost
Roof, glazing, walls
Usual measures
Flat roofs, dry lining, glazing and shopfronts, HVAC, solar, LED
Watch-outs
Measured per m² after survey

Priced after survey

Warehouses, factories and industrial units

Typical construction
Steel portal frame, profiled cladding
Where heat is lost
Roof and cladding
Usual measures
Over-roof and roof liner insulation, rooflights, solar PV, battery storage, EV charging
Watch-outs
Measured per m² after survey

Priced after survey

Schools, colleges and nurseries

Typical construction
Mixed
Where heat is lost
Roofs, walls, glazing
Usual measures
Roofs, EWI, glazing, heat pumps, solar
Watch-outs
Works planned around term times

Priced after survey

Hotels, restaurants and gyms

Typical construction
Mixed
Where heat is lost
Roofs, walls, glazing
Usual measures
Roofs, walls, glazing, HVAC and heat recovery
Watch-outs
Phased works to keep trading

Priced after survey

Care homes and healthcare

Typical construction
Mixed
Where heat is lost
Walls, roofs, heating
Usual measures
EWI, roofs, glazing, heating, ventilation (occupied-building methods)
Watch-outs
Occupied-building methods and fire safety

Priced after survey

Places of worship and heritage buildings

Typical construction
Historic fabric
Where heat is lost
Walls, roof, windows
Usual measures
Breathable insulation, secondary glazing, heating controls
Watch-outs
Consents and breathable materials

Priced after survey

Mixed-use

Typical construction
Mixed
Where heat is lost
Floors over commercial units, walls, roof
Usual measures
Floors over commercial units, EWI, roofs, acoustic insulation
Watch-outs
Separate residential and commercial requirements

Priced after survey

Landlord and housing association portfolios

Typical construction
Mixed stock
Where heat is lost
Varies by property
Usual measures
Stock surveys, EPC C plans, programme delivery across many homes
Watch-outs
Private rented homes must reach EPC C by October 2030

Priced after survey

Begin your project

Not sure where your home fits?

Our EPC Check & Upgrade Planner asks your property type first, then ranks every upgrade by value — with the grants that may apply.

CallWhatsAppGet a quote